17-2 z.one ultra and z.one ultra sp OPERATOR MANUAL
Curved Array
Transducer
Identified by the letter C (curved) and a pair of numbers (6-2) = e.g., C6-2. The
numbers corresponds to the optimum frequency bandwidth expressed in MHz.
The transducer elements are electrically configured to control the characteristics
and direction of the acoustic beam.
DDP Data Display Box: The DDP is a reserved space in the bottom-right corner of the
image area (on the LCD Display) in which information is displayed about depth of
measurement cursor, velocity, and other assorted calculation values.
DICOM Digital Imaging and Communication in Medicine: An industry standard used for
the storage and printing of digital imaging and associated measurement data files
across a wide spectrum of disciplines in the medical field.
Dual Imaging feature allowing simultaneous display of two different images on the
screen, operating in different modalities (i.e. Color Flow and Power Doppler)
FDA Food and Drug Administration: A government agency responsible for ensuring
safety to humans in the use of products produced or sold/used in the United
States of America.
Harmonics Harmonic imaging: An imaging feature that can be selected on the z.one ultra,
which transmits at one frequency and receives at a higher harmonic frequency to
reduce noise and clutter and improve resolution.
JPEG Joint Photographic Experts Group: The original name of the committee that wrote
the JPEG image file standard, that is designed for compressing either full-color or
gray-scale images.
Linear Array
Transducer
Identified by the letter L (linear) and a pair of numbers (10-5) = e.g., L10-5. The
numbers corresponds to the optimum frequency bandwidth expressed in
MHz.The transducer elements are electrically configured to control the
characteristics and direction of the acoustic beam.
M-Mode Motion Mode: A way to show the motional behavior of cardiac structures (valves,
heart wall, etc.). A single beam of ultrasound is transmitted and reflected signals
are displayed as dots of varying intensities in a time axis display.
MI Mechanical Index: An indication of the likelihood of mechanical bio effects
occurring. The higher the MI value, the greater the likelihood of mechanical bio
effects.
MPPS Modality Performed Procedure Step: An advanced DICOM service function.
MPPS consists of a network connection between the z.one ultra and a HIS/RIS
management system. The MPPS service allows for defining specific imaging
sequences (steps) to be performed on the patient, and transfer of resultant
images and data, based upon a specific clinical modality.
NTSC National Television Standards Committee: A video standard format setting used in
the United States, and a number of other countries worldwide. See also PAL.